MODEL
FPFK
Pilot operated, normally closed, electro-proportional throttle with reverse flow
check
SERIES 2 / CAPACITY: 80 L/min. / CAVITY: T-5A
X-Control
CONFIGURATION
X Control No Manual Override
D Flow
Rate
Nominal 20 gpm @ 200 psi (14 bar)
differential (80 L/min.)
N Seal
Material
Buna-N
(none) Coil No coil
This valve is a pilot-operated, normally closed, electro-proportional throttle with reverse free-flow check. Energizing
the coil generates an opening force on the pilot stage which vents the main stage poppet to open proportionally.
Metered flow is from port 1 to port 2 with reverse free flow from port 2 to port 1.
TECHNICAL DATA
Cavity T-5A
Series 2
Capacity 80 L/min.
Recommended dither frequency 100 Hz
Maximum Valve Leakage at 110 SUS (24 cSt) 20 drops/min.@5000 psi
Manual Override Force Requirement 33 N/100 bar @ Port 1
Deadband, nominal (as a percentage of input) 25%
Manual Override Stroke 1,50 mm
Solenoid Tube Diameter 19 mm
Valve Hex Size 28,6 mm
Valve Installation Torque 61 - 68 Nm
Model Weight (with coil) 0,55 kg
Seal kit - Cartridge Buna: 990203007
Seal kit - Cartridge EPDM: 990203014
Seal kit - Cartridge Viton: 990203006
Seal and nut kit - Coil Viton: 990770006
Model Weight 0.41 kg.
(X)CONTROL
X No Manual Override
E Twist (Extended) Manual Override
M Manual Override
(D)FLOW RATE
D Nominal 20 gpm @ 200 psi (14 bar)
differential (80 L/min.)
B Nominal 10 gpm @ 200 psi (14 bar)
differential (40 L/min.)
(N)SEAL MATERIAL
N Buna-N
E EPDM
V Viton
COIL *
No coil
212 DIN 43650-Form A, 12 VDC
224 DIN 43650-Form A, 24 VDC
712 Twin Lead, 12 VDC
724 Twin Lead, 24 VDC
912 Deutsch DT04-2P, 12 VDC
924 Deutsch DT04-2P, 24 VDC
* Additional coil options are available
snhy.com/
FPFK
TECHNICAL FEATURES
Capable of operating with pressures up to 5000 psi (350 bar).
Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
This cartridge has several manual override choices, including no manual override. See Option Configuration.
Model Code Example: FPFKXDNCONFIGURATION OPTIONS